We’ve upgraded how sensitive data is protected. Prospect now uses a personal vault instead of the previous encryption key. Your vault gives you secure, private access to protected organization data. Click the Vault icon in the top menu to complete the setup. Nous avons amélioré la protection des données sensibles. Prospect utilise désormais un coffre personnel au lieu de l’ancienne clé de chiffrement. Votre coffre vous donne un accès sécurisé et privé aux données protégées de votre organisation. Cliquez sur l’icône Coffre dans le menu supérieur pour finaliser la configuration.
08.07.2026 10:35

Dashboard Update - July 2026

We’ve updated the dashboards. If you experience loading or display issues, please clear your cookies and browser cache. Nous avons mis à jour les tableaux de bord. Si vous constatez des problèmes d’affichage, veuillez vidervos cookies et le cache de votre navigateur.
08.07.2026 10:34

Documentation: shs_ts

Time Series data of individual Solar Home Systems
To import data in this format you can use our API. -> Api Documentation
Rate limit: 300 requests per minute. Once the limit is exceeded, any further requests will result in a 429 (Too Many Requests) response.
You can also supply us with files in xlsx, csv or json format. -> Example CSV
Row Name Type Example

manufacturer *

Manufacturer of the device

  • * required
string

A2EI

serial_number *

Serial of the device

  • * required
string

ABC/123

metered_at *

time the metrics apply to (not time of query)

  • * required
datetime

2021-05-03 6:23:55

data_origin

Origin of the data, generic or name of the api

  • auto-generated
string

generic

custom

Saves additional imported data out of standard structure

  • auto-generated
jsonb

{ "some": "key" }

organization_id

References Organization of data

  • auto-generated
integer

1

import_id

References Import of data

  • auto-generated
integer

1

source_id

References Source of data

  • auto-generated
integer

1

updated_at

Timestamp when row was updated

  • auto-generated
datetime

2021-05-03 6:23:55

created_at

Timestamp when row was inserted

  • auto-generated
datetime

2021-05-03 6:23:55

paygo_days_left

days left until next payment (only used until system is paid off)

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

integer

7

paygo_is_paid_off

system is permanently unlocked

boolean

true

interval_seconds

for remotely monitored systems, interval between measurements

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

integer

360

output_energy_interval_wh

energy consumption at time interval system to customer in watt-hour

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float

123.456

output_energy_lifetime_wh

cumulative energy reading system to customer in watt-hour

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float

123.456

pv_energy_interval_wh

energy production at time interval PV to system in watt-hour

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float

123.456

pv_energy_lifetime_wh

cumulative energy reading PV to system in watt-hour

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float

123.456

grid_energy_interval_wh

energy consumption at time interval grid to system in watt-hour

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float

123.456

grid_energy_lifetime_wh

cumulative energy reading grid to system in watt-hour

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float

123.456

system_output_w

system output to customer in watts

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float

123.456

battery_charge_percent

battery charge level in percentage

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float

76.8

battery_io_w

battery input / output in watts (>0 = charging)

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float

-37.58

battery_v

battery voltage in volts

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float

23.6

grid_input_v

grid input voltage in volts

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float

212.7

grid_input_w

grid to system in watts

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float

123.456

pv_input_w

PV to system in watts

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float

123.456

device_uid

organization_id + manufacturer + serial_number; FK from shs table